Find the latest electrical news, job photos and much more!! Feel free to browse our collection of articles related to our field, tricks-of-the-trade, amazing videos and other important industry information. Members can add their own or send it to us and we will post it. Do you have any pictures of electrical work you would like to share, good or bad, send them to us at:
info@electriciansworld.com and we will post them for all to view. Be sure to include any information to help explain the photo.
These photos can be a great lesson to a lot of people, so lets share as many as we can!!(jpeg format is best)
| Found 105 records | |
Showing page 1 of 11 pages |
|
|
Is it really worth it? The time involved to make this repair and the potential further damage that could have been caused, and almost did! Just go to the store and buy another.
More info »
A so called friend and self proclaimed "licensed electrician" installed this for a customer. Charged top dollar and told them it would solve their electrical problems in the house. Well, no it didn't! and it made it worse!
More info »
This is the view from the front. Not only could they not combine the switches and make one 2 gang box nice and neat, but they didn't even use an electrical box for the second switch.
More info »
Look closely in this picture and see how much is there. Hidden behind the tiles in an office building. Nothing like removing old electrical and making it safe.
More info »
Another example of water sneaking in the main electrical panel along the feed wires. You can see on the neutral lug a drip of water ready to fall and that over time will cause an electrical failure.
More info »
How is this for moving the smoke detector to the drop ceiling? The home inspector wrote the report because the smoke detectors didn't work, but if he opened up a ceiling tile he would have seen a lot more!!!
More info »
This is amazing! 100A Main electrical panel inside a bedroom closet. Down low and very unsafe. Water entering and causing electrical problems due to crappy installation. Caught just in time, as you can see the corrosion and damage done by the arcing!
More info »
The problem is NOT from water getting in the meter pan from the outside!!! The real problem is when the water goes in the coating of the SEC and then runs through it to enter at all connection points. By just following the path of the wires.
More info »
This was a fan box on a drop ceiling. How do you like that use of romex? Probably had some extra after they tied the ladders down on the truck;)! Take a close look and you can see they even skinned the romex to support the drop ceiling too!
More info »